Portable BOD (Biochemical Oxygen Demand) |
|
|
|
|
|
Type |
: |
BOD W-50 |
|
|
|
|
|
Negara Asal |
: |
USA |
|
|
|
|
|
Fungsi |
: |
Untuk mngukur dan menguji kebutuhan oksigen biologis untuk memecah |
|
|
|
bahan buangan di dalam air oleh mikroorganisme. |
|
Features: |
|
|
|
|
|
|
• |
Probe-body tapered to fit into a stanard 300 mL BOD bottle & International Versions |
|
|
• |
No warm-up time required |
|
|
|
|
|
|
• |
Self-stirring to provide representative sample & increase respons times |
|
|
|
• |
User-replaceable, low-maintance sensor with ± 1 year life |
|
|
|
|
• |
Smart sensor retains calibration in the probe |
|
|
|
|
|
• |
Extremely quiet operation |
|
|
|
|
|
|
• |
Free Data Manager Software |
|
|
|
|
|
|
• |
Aplikasi Pelaporan Hasil Uji (APHU) secara on-line |
|
|
|
|
Spesifikasi : |
|
|
|
|
|
|
• |
Accuracy |
|
: mg/L |
|
0-20 mg/L, ± 0.1 mg/L or ± 1% reading, whichever greater; 20-50 mg/L, ± 15% reading |
|
|
|
|
: % air |
|
0-200%, ±1% reading or ±1%, whichever greater; 200-500%, ±15% reading |
|
|
|
|
: temperature |
±0.2° C |
|
|
• |
Range |
|
: mg/L |
|
0-50 mg/L |
|
|
|
|
|
: % air |
|
0-500% air saturation |
|
|
|
|
: temperature |
Ambient (10 to +40° C); Compensation (-5 to +50° C) |
• |
Resolution |
|
: mg/L |
|
0.01 |
|
|
|
|
|
|
: % air |
|
0.1% |
|
|
|
|
|
|
: temperature |
0.1° C |
|
|
• |
Warranty |
|
: 2-years; 1-year sensor cap |
|
|
|
• |
Cable Length |
|
: 2-meters (6 feet) |
|
|
|
• |
Power |
|
: External 110-230 VAC power supply with DC input to sensor |
• |
Sensor Type |
|
: Optical; dynamic luminescence quenching lifetime detection |
• |
Response Time |
|
: T95 = 22 seconds with stirring; T95 = 40 seconds without stirring |
• |
IP Rating |
|
: IP-65 |
|
|
|
|
• |
Certifications |
|
: RoHS, CE, WEEE, Assembled in USA (ISO 9001 & ISO 14001) |
ProODO BOD System Specifications (instrument with cable and probe) |
|
|
|
• |
Dissolved Oxygen |
|
Sensor Type |
|
: Optical (dynamic luminescence quenching lifetime detection) |
|
(% saturation) |
|
Range |
|
: 0 to 500% air saturation |
|
|
|
|
Accuracy |
|
: 0 to 200% air saturation ± 1% of the reading or ± 1% air saturation, whichever is greater; |
|
|
|
|
|
|
: 200 to 500% air saturation ± 10% of the reading |
|
|
|
|
Resolution |
|
: 0.1% air saturation |
• |
Dissolved Oxygen |
|
Sensor Type |
|
: Optical (dynamic luminescence quenching lifetime detection) |
|
(mg/L) |
|
Range |
|
: 0 to 50 mg/L |
|
|
|
|
Accuracy |
|
: 0 to 20 mg/L ± 0.1 mg/L or ± 1% of reading, whichever is greater; |
|
|
|
|
|
|
: 20 to 50 mg/L ± 10% of the reading |
|
|
|
|
Resolution |
|
: 0.01 or 0.1 mg/L (auto-scaling) |
• |
Temperature |
|
Range |
|
: -5 to 70°C |
|
|
(°C, °F, °K) |
|
Accuracy |
|
: ± 0.2°C |
|
|
|
|
|
Resolution |
|
: 0.1°C |
|
|
|
Barometer |
|
Range |
|
: 375 to 825 mmHg |
|
(mmHg, inHg, mBar, Psi, KPa) |
|
Accuracy |
|
: ± 1.5 mmHg from 0 to 50°C |
|
|
|
|
Resolution |
|
: 0.1 mmHg |
|