| Portable BOD (Biochemical Oxygen Demand) | ||||||||
| Type | : | BOD W-50 | ||||||
| Negara Asal | : | USA | ||||||
| Fungsi | : | Untuk mngukur dan menguji kebutuhan oksigen biologis untuk memecah | ||||||
| bahan buangan di dalam air oleh mikroorganisme. | ||||||||
| Features: | ||||||||
| • | Probe-body tapered to fit into a stanard 300 mL BOD bottle & International Versions | |||||||
| • | No warm-up time required | |||||||
| • | Self-stirring to provide representative sample & increase respons times | |||||||
| • | User-replaceable, low-maintance sensor with ± 1 year life | |||||||
| • | Smart sensor retains calibration in the probe | |||||||
| • | Extremely quiet operation | |||||||
| • | Free Data Manager Software | |||||||
| • | Aplikasi Pelaporan Hasil Uji (APHU) secara on-line | |||||||
| Spesifikasi : | ||||||||
| • | Accuracy | : mg/L | 0-20 mg/L, ± 0.1 mg/L or ± 1% reading, whichever greater; 20-50 mg/L, ± 15% reading | |||||
| : % air | 0-200%, ±1% reading or ±1%, whichever greater; 200-500%, ±15% reading | |||||||
| : temperature | ±0.2° C | |||||||
| • | Range | : mg/L | 0-50 mg/L | |||||
| : % air | 0-500% air saturation | |||||||
| : temperature | Ambient (10 to +40° C); Compensation (-5 to +50° C) | |||||||
| • | Resolution | : mg/L | 0.01 | |||||
| : % air | 0.1% | |||||||
| : temperature | 0.1° C | |||||||
| • | Warranty | : 2-years; 1-year sensor cap | ||||||
| • | Cable Length | : 2-meters (6 feet) | ||||||
| • | Power | : External 110-230 VAC power supply with DC input to sensor | ||||||
| • | Sensor Type | : Optical; dynamic luminescence quenching lifetime detection | ||||||
| • | Response Time | : T95 = 22 seconds with stirring; T95 = 40 seconds without stirring | ||||||
| • | IP Rating | : IP-65 | ||||||
| • | Certifications | : RoHS, CE, WEEE, Assembled in USA (ISO 9001 & ISO 14001) | ||||||
| ProODO BOD System Specifications (instrument with cable and probe) | ||||||||
| • | Dissolved Oxygen | Sensor Type | : Optical (dynamic luminescence quenching lifetime detection) | |||||
| (% saturation) | Range | : 0 to 500% air saturation | ||||||
| Accuracy | : 0 to 200% air saturation ± 1% of the reading or ± 1% air saturation, whichever is greater; | |||||||
| : 200 to 500% air saturation ± 10% of the reading | ||||||||
| Resolution | : 0.1% air saturation | |||||||
| • | Dissolved Oxygen | Sensor Type | : Optical (dynamic luminescence quenching lifetime detection) | |||||
| (mg/L) | Range | : 0 to 50 mg/L | ||||||
| Accuracy | : 0 to 20 mg/L ± 0.1 mg/L or ± 1% of reading, whichever is greater; | |||||||
| : 20 to 50 mg/L ± 10% of the reading | ||||||||
| Resolution | : 0.01 or 0.1 mg/L (auto-scaling) | |||||||
| • | Temperature | Range | : -5 to 70°C | |||||
| (°C, °F, °K) | Accuracy | : ± 0.2°C | ||||||
| Resolution | : 0.1°C | |||||||
| Barometer | Range | : 375 to 825 mmHg | ||||||
| (mmHg, inHg, mBar, Psi, KPa) | Accuracy | : ± 1.5 mmHg from 0 to 50°C | ||||||
| Resolution | : 0.1 mmHg | |||||||